|
CoreValve Inc
sapien xt Sapien Xt, supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt/pm30503595-94-19-16 Average 90 stars, based on 1 article reviews
sapien xt - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CoreValve Inc
tavr valve type bev (sapien xt) a ." width="250" height="auto" />Tavr Valve Type Bev (Sapien Xt), supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/tavr+valve+type+bev++sapien+xt+/pmc10283153-5-0-9 Average 90 stars, based on 1 article reviews
tavr valve type bev (sapien xt) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CoreValve Inc
tavr sapien a ." width="250" height="auto" />Tavr Sapien, supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/tavr+device+sapien+xt/pm27151607-94-12-15 Average 90 stars, based on 1 article reviews
tavr sapien - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CoreValve Inc
prostheses 26-/29-mm sapien xt/sapien 3 a ." width="250" height="auto" />Prostheses 26 /29 Mm Sapien Xt/Sapien 3, supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/prostheses+26++29+mm+sapien+xt+sapien+3/pm39967226-25-15-23 Average 90 stars, based on 1 article reviews
prostheses 26-/29-mm sapien xt/sapien 3 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CoreValve Inc
thv sapien 3 a ." width="250" height="auto" />Thv Sapien 3, supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt+thv/pmc11308846-80-9-13 Average 90 stars, based on 1 article reviews
thv sapien 3 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Intuity Medical
edwards sapien xt 23 a ." width="250" height="auto" />Edwards Sapien Xt 23, supplied by Intuity Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/edwards+sapien+xt+23/pm34791144-113-44-41 Average 90 stars, based on 1 article reviews
edwards sapien xt 23 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Edwards Lifesciences Inc
sapien xt ![]() Sapien Xt, supplied by Edwards Lifesciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt/pmc09550344-75-34-39 Average 90 stars, based on 1 article reviews
sapien xt - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Edwards Lifesciences Inc
23-mm sapien xt ![]() 23 Mm Sapien Xt, supplied by Edwards Lifesciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/23+mm+sapien+xt/pm28669505-103-20-22 Average 90 stars, based on 1 article reviews
23-mm sapien xt - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Edwards Lifesciences Inc
sapien xt thv [sxt] ![]() Sapien Xt Thv [Sxt], supplied by Edwards Lifesciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt+thv/pm21777881-32-3-9 Average 90 stars, based on 1 article reviews
sapien xt thv [sxt] - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CoreValve Inc
sapien xt valve ![]() Sapien Xt Valve, supplied by CoreValve Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt+valve/pmc08825546-316-5-11 Average 90 stars, based on 1 article reviews
sapien xt valve - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Edwards Lifesciences Inc
balloon-expandable prostheses ![]() Balloon Expandable Prostheses, supplied by Edwards Lifesciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+xt+23+mm/pm25060368-29-8-16 Average 90 stars, based on 1 article reviews
balloon-expandable prostheses - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Alterra Power
sapien tpv (xt and s3) ![]() Sapien Tpv (Xt And S3), supplied by Alterra Power, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sapien+xt/sapien+tpv++xt+and+s3+/pmc09032030-241-18-25 Average 90 stars, based on 1 article reviews
sapien tpv (xt and s3) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
a ." width="100%" height="100%">
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Characteristics of trials included in the metanalysis
Article Snippet:
Techniques:
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Comparison of balloon expandable platform vs. self-expanding platforms in high risk patients undergoing TAVR, BEV is associated with reduced risk of all-cause mortality at 30 days compared with SEV ( A ). The sub-group difference was not significant when the studies were stratified for the type of study ( B ). BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.
Article Snippet:
Techniques: Comparison
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Comparison of balloon expandable platform with old generation self-expanding platforms for to assess the role of study type (RCTs comparing BEV vs. SEV head to head with post-hoc and pre-specified analyses of RCTs) showing no between-the-group difference on the result. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, trans-catheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.
Article Snippet:
Techniques: Comparison
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Comparison of balloon expandable platform vs. self-expanding platforms for cardiovascular mortality ( A ), stroke ( B ) and early safety ( C ) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.
Article Snippet:
Techniques: Comparison
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Comparison of balloon expandable platform vs. self-expanding platforms for implantation of >1 valve per procedure ( A ), moderate to severe AR/PVL ( B ), new PPM requirement ( C ), and device success as defined by VARC ( D ) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; AR, aortic regurgitation; PVL, para valvular leak; PPM, permanent pacemaker; TAVR, transcatheter aortic valve replacement; VARC, valve academic research consortium; M-H, Mantel-Haenszel; CI, confidence interval.
Article Snippet:
Techniques: Comparison
Journal: Frontiers in Cardiovascular Medicine
Article Title: The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis
doi: 10.3389/fcvm.2023.1130354
Figure Lengend Snippet: Comparison of balloon expandable platform vs. self-expanding platforms for life-threatening bleeding ( A ), major vascular complications ( B ), acute kidney injury ( C ), and atrial fibrillation ( D ) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.
Article Snippet:
Techniques: Comparison
Journal: Cardiology Journal
Article Title: Systemic inflammation and oxidative stress contribute to acute kidney injury after transcatheter aortic valve implantation
doi: 10.5603/CJ.a2020.0169
Figure Lengend Snippet: Multivariate logistic regression analysis for predictors of acute kidney injury after transcatheter aortic valve implantation.
Article Snippet: We prospectively included 105 consecutive patients with severe aortic stenosis, who underwent TAVI either via a transfemoral (TF TAVI, n = 60) or a transapical approach (TA TAVI, n = 45) using Edwards-Sapien and
Techniques:
Journal: Cardiology Journal
Article Title: Systemic inflammation and oxidative stress contribute to acute kidney injury after transcatheter aortic valve implantation
doi: 10.5603/CJ.a2020.0169
Figure Lengend Snippet: Levels of inflammatory markers and oxidative stress after transcatheter aortic valve implantation (TAVI) by stage of acute kidney injury (AKI); A. 22–26 h after TAVI; B. 44–52 h after TAVI. One-way ANOVA, followed by Tukey post-hoc test performed if ANOVA was significant, *p < 0.05 from post hoc test significant difference against group with no postprocedural AKI. The magnitude of inflammatory reaction measured by levels of tumor necrosis factor alpha (TNF α ) and its receptors, myeloperoxidase (MPO) and C-reactive protein (CRP) 22–26 h after TAVI was higher in all patients who developed AKI regardless of its severity. On the other hand, 44–52 h after TAVI inflammatory markers remained high, but only in patients who developed AKI stage 2/3.
Article Snippet: We prospectively included 105 consecutive patients with severe aortic stenosis, who underwent TAVI either via a transfemoral (TF TAVI, n = 60) or a transapical approach (TA TAVI, n = 45) using Edwards-Sapien and
Techniques:
Journal: Cardiology Journal
Article Title: Systemic inflammation and oxidative stress contribute to acute kidney injury after transcatheter aortic valve implantation
doi: 10.5603/CJ.a2020.0169
Figure Lengend Snippet: Changes in inflammatory markers and oxidative stress after transfemoral (TF) and transapical (TA) group 4–6 h, 22–26 h, and 44–52 h post-procedure. A. High-sensitivity C-reactive protein (hsCRP); B. Myeloperoxidase (MPO); C. Aldosterone; D. Tumor necrosis factor alpha (TNF α ); E. TNF α R1; F. TNF α R2. Two-way ANOVA followed by Bonferroni post hoc test, *p < 0.05. Levels of hsCRP, MPO, aldosterone, and TNF α R1 and TNF α R2 were significantly higher after TA transcatheter aortic valve implantation.
Article Snippet: We prospectively included 105 consecutive patients with severe aortic stenosis, who underwent TAVI either via a transfemoral (TF TAVI, n = 60) or a transapical approach (TA TAVI, n = 45) using Edwards-Sapien and
Techniques:
Journal: Cardiology Journal
Article Title: Systemic inflammation and oxidative stress contribute to acute kidney injury after transcatheter aortic valve implantation
doi: 10.5603/CJ.a2020.0169
Figure Lengend Snippet: Changes in neurohormonal activation in acute kidney injury (AKI) and no AKI group 4–6 h, 22–26 h, and 44–52 h post-procedure. A. Neutrophil gelatinase-associated lipocalin (NGAL); B. Interleukin 6; C. N-terminal pro-B-type natriuretic peptide (NT-proBNP), D. Receptor for interleukin 33 (ST2); Two-way ANOVA followed by Bonferroni post hoc test, *p < 0.05. NGAL levels were higher pre-transcatheter aortic valve implantation (TAVI) and were rising after the procedure significantly more in the AKI group. Interleukin 6 levels increase after TAVI from 4–6 h continuing rise over next hours. The rise in interleukin 6 levels was significantly higher in the AKI group at 22–26 h and 44–52 h. BNP and ST2 levels were rising significantly only in the AKI group at 22–26 h and 44–52 h.
Article Snippet: We prospectively included 105 consecutive patients with severe aortic stenosis, who underwent TAVI either via a transfemoral (TF TAVI, n = 60) or a transapical approach (TA TAVI, n = 45) using Edwards-Sapien and
Techniques: Activation Assay
Journal: Annals of Translational Medicine
Article Title: Outcomes of transcatheter aortic valve replacement for pure native aortic regurgitation with the use of newer- vs. early-generation devices
doi: 10.21037/atm-21-6936
Figure Lengend Snippet: Procedural characteristics, immediate results, and clinical outcomes of the study patients
Article Snippet: We implanted a 29 mm
Techniques:
Journal: Annals of Translational Medicine
Article Title: Outcomes of transcatheter aortic valve replacement for pure native aortic regurgitation with the use of newer- vs. early-generation devices
doi: 10.21037/atm-21-6936
Figure Lengend Snippet: Positioning the CoreValve often proved to be very difficult because of the turbulence due to the pure native aortic regurgitation. The valve may be deployed too deeply into the left ventricle and causes moderate to severe residual paravalvular leakage (PVL). In our series, all of the PVL complicating low deployments of a CoreValve prosthesis were treated by transcatheter insertion (“TAVR-in-TAVR”) of a second transcatheter heart valve. (A) In one of the patients needing CoreValve-in-CoreValve implantation, significant residual PVL was evident, owing to a lack of radial strength of the second 31 mm CoreValve to afford enough stent expansion of the first 31 mm CoreValve. The diameter of the first CoreValve frame at its waist was 24.0 mm (black double arrow), occupying the annulus in this case. Implantation of the second CoreValve increased the diameter at the waist from 24.0 to 25.6 mm (white double arrow), with significant recoil (B). In another patient with low deployment of a 31 mm CoreValve prosthesis, the diameter of the device at the aortic annulus was 27.6 mm (black double arrow) and 24.0 mm at its waist (dashed black double arrow) (C). We implanted a 29 mm Sapien XT valve in the malpositioned CoreValve in order to eliminate the residual PVL. The final diameters both at the annulus (white double arrow) and the waist (dashed white double arrow) were 29.2 mm (D).
Article Snippet: We implanted a 29 mm
Techniques:
Journal: Children
Article Title: Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease
doi: 10.3390/children9040497
Figure Lengend Snippet: Transcatheter pulmonary valve replacement using a Medtronic Melody Valve. ( A ) Lateral angiogram showing a stenotic (arrow) RV-PA conduit; there is mild calcification. ( B ) The RV-PA conduit is prepared to receive the Melody valve by placement of a pre-stent (lighter stent frame). Also seen is the partially expanded Melody valve within the pre-stent (darker stent frame). ( C ) Excellent angiographic result with a well-positioned transcatheter Melody valve; note there is no pulmonary regurgitation. PA = pulmonary artery, RVOT = right ventricular outflow tract.
Article Snippet: In the United States, there are now 4 FDA approved TPV therapies, Melody TPV , Harmony TPV ,
Techniques:
Journal: Children
Article Title: Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease
doi: 10.3390/children9040497
Figure Lengend Snippet: Transcatheter pulmonary valve replacement using an Edwards-Sapien XT valve. ( A ) Lateral angiogram showing a stented RVOT. ( B ) The angiogram shows Sapien valve (dark frame) deployment within the distal portion of the pre-stent. MPA = main pulmonary artery, RVOT = right ventricular outflow tract.
Article Snippet: In the United States, there are now 4 FDA approved TPV therapies, Melody TPV , Harmony TPV ,
Techniques:
Journal: Children
Article Title: Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease
doi: 10.3390/children9040497
Figure Lengend Snippet: Transcatheter pulmonary valve replacement using Medtronic Harmony TPV. ( A ) Cranially angulated right anterior oblique projections showing the Harmony TPV (arrow) immediately after release. The delivery system is still across the valve. ( B ) Pulmonary artery angiogram shows unobstructed flow into the pulmonary artery branches. Note there is no pulmonary regurgitation.
Article Snippet: In the United States, there are now 4 FDA approved TPV therapies, Melody TPV , Harmony TPV ,
Techniques:
Journal: Children
Article Title: Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease
doi: 10.3390/children9040497
Figure Lengend Snippet: Transcatheter pulmonary valve replacement using Alterra pre-stent with Edwards-Sapien S3 TPV. ( A ) Lateral fluoroscopy projection showing Alterra Pre-stent (light stent frame) deployed. The Sapien S3 valve is positioned for deployment. ( B ) Lateral fluoroscopy projection showing the Sapien S3 valve (dark frame) deployed inside the Alterra Pre-stent (light frame).
Article Snippet: In the United States, there are now 4 FDA approved TPV therapies, Melody TPV , Harmony TPV ,
Techniques:
Journal: Children
Article Title: Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease
doi: 10.3390/children9040497
Figure Lengend Snippet: Intracardiac echocardiography (ICE) to assess for early failure of an Edwards-Sapien S3 TPV. The ICE probe is placed in the right ventricular outflow tract. ( A ) The TPV is seen in the open position. The medial leaflet (arrow) is shortened, thickened, and has limited systolic excursion. ( B ) When the TPV closes there is failure of coaptation of the leaflets (arrow) with resultant pulmonary regurgitation (not shown). ( C ) A new valve-in-valve Edwards-Sapien S3 was placed. ICE image now shows that the leaflets (arrows) are of the same length, thin, and show normal systolic excursion. ( D ) When the TPV closes the leaflets show excellent coaptation (arrow) and there is no pulmonary regurgitation (not shown). RVOT=right ventricular outflow tract, PA=pulmonary artery.
Article Snippet: In the United States, there are now 4 FDA approved TPV therapies, Melody TPV , Harmony TPV ,
Techniques: